Skip to content

System Settings

System settings cover all management interface options required for daily device operation and maintenance. It is recommended to check each item after deployment.

This page allows you to adjust volume, voice TTS synthesis method, broadcast testing, and upload custom alert tones.

Voice Synthesis Method

Auto: When a network connection is available, the online environment is used automatically.

Offline Only: Regardless of network conditions, only offline voice synthesis is used.

Voice Type: Voice broadcasts support both offline and online male/female voice options.

Speech Rate: Global voice broadcast speed setting, range: 1-10 (default: 5).

Disable Speaker When Headphones Connected: Whether to disable the built-in speaker when an audio output device is connected. The change will take effect on the next broadcast after toggling the switch.

Test Alert Tone

Selectable from built-in alert tones and uploaded custom alert tones. The numeric part of the alert tone name is the tone number, which can be used when selecting alert tones for voice broadcasts and in API calls. Tones starting with 0 are built-in alert tones, and those starting with 1 are uploaded custom alert tones.

Alert Tone Operation Buttons: The buttons are Test, Rename, and Delete. Built-in alert tones only support testing.

Upload Alert Tone

The device supports up to 50 custom tones, numbered 100–149. wav and mp3 are supported, up to 5 MB each.
The device generates a random file name and assigns the number. Built-in tones are numbered 0–99 and can only be previewed.

See Notification Groups & Tones for upload, rename, and delete rules.

After uploading, a number and random filename will be automatically generated, and a naming dialog will appear.

Used to set the current time and NTP server. When automatic synchronization is enabled, the time cannot be adjusted manually, and the system will automatically synchronize.

You can modify the settings according to your needs.

This feature is used to configure automatic log cleanup. It displays the last cleanup time and allows you to select the cleanup scope.

The cleanup scope includes all viewable logs in the log management interface. Cleanup is performed once daily.

Configure button functions. You can separately configure the functions for long press and short press.

Configure the email sending server used when sending emails upon host monitoring alerts.

Uses SMTP protocol. The corresponding SMTP service must be enabled before use.

Security settings are primarily used to configure the alarm light backend login password.

The current firmware does not verify API signatures, so no API key is required. See Login & Account.

Standby recovery time: The time elapsed before the standby style is restored after an alert interrupts it.

LED Style: The light style for standby mode.

Color: The LED color for standby mode.

Style parameters: LED style parameter settings that allow for style diversity adjustments. After selecting a specific LED style, hover over Style Parameters to view the specific style.

Style Parameter Descriptions

  1. Blink, Breathing

    ValueDescription
    0Single color, never changes color
    0.5Single color, gradually changes color
    10-360 degree hue gradient. The top layer of the LED is the initial color.
    The bottom layer is the hue after adding the specified degrees. Middle layers are gradient colors.
  2. Snake

    ValueDescription
    0Single color
    1Multi-color
  3. Ease Circle

    ValueDescription
    0Specified color unchanged, draws circle top to bottom
    1Specified color unchanged, draws circle at random position
    2Specified color shifts 30 degrees each time, draws circle top to bottom
    3Specified color shifts 30 degrees each time, draws circle at random position
  4. Gradient

    ValueDescription
    0~10-360 degree hue gradient. The top layer of the LED is the initial color.
    The bottom layer is the hue after adding the specified degrees. Middle layers are gradient colors.
  5. Lighthouse and Flame effects have no style parameters.

Notification groups define the LED style, color, tone, voice, repeat count, interval, quiet hours, and email notification. Monitor items, custom APIs, and Modbus commands can reference a group as their alarm style.

See Notification Groups & Tones for creation, editing, deletion, testing, and tone management.

This page is used to modify the alarm light’s wired network settings.

You can choose to configure a static IP address or dynamic IP address. You can also view the IPv6 address.

After filling in the information, click the Save button to apply the configuration. After configuration, the alarm light will announce the new network information via voice.

This page allows you to configure the alarm light’s wireless network (Wi-Fi).

After turning on the Wi-Fi switch, the wireless network list will be automatically refreshed. You can also view network adapter details and refresh the list.

Click the Refresh button to refresh the WiFi list.

Click the Adapter Details button to display the MAC address and network information of the alarm light’s wireless adapter.

Connecting to a Wireless Network

Select the wireless network you want to connect to from the wireless network list, click the Connect button, and a password input dialog will appear. Enter the password, click Connect, and after a moment, the alarm light will announce the success message and network information via voice when connected.

Setting Wireless Network Address

First connect to the wireless network. After successful connection, click the Advanced button to enter advanced settings. Then fill in the relevant network information according to your actual situation and click Save.

After successful configuration, the network information will be announced via voice.

Deleting a Wireless Network

In the network list, click the Delete button, and a confirmation dialog will appear. Click confirm to delete the wireless network.

Disconnecting a Wireless Network

In the network list, a Disconnect button will appear next to connected wireless networks. Click Disconnect to disconnect the wireless network, and a voice prompt will be given.

Click the Routing Table tab to view the current device’s routing information.

When both the accessing device and the device’s local network environment support IPv6, the device’s local network allows IPv6 access.

In this case, the accessing device can directly access the device via its IPv6 address without the need for port forwarding or other operations on the device’s local network.

This device supports automatic IPv6 address acquisition. When network conditions are supported, the IPv6 address will be automatically obtained.

When accessing the device directly via an IPv6 address in the browser, the address format is http://[IPv6 Address].

This page provides factory reset, backup creation, and backup restore functions.

Factory Reset

Click the Execute button, then click confirm in the warning dialog to perform a factory reset.

Create Backup

Click the Create Backup button to create a backup of the current configuration.

Restore Backup

  • Method 1: Click the Upload Backup and Restore button, select a file to upload. After clicking confirm, the file will be uploaded and the backup will be restored.
  • Method 2: In the backup list, select a backup and click the Restore button. The device will use the selected file to perform the restore operation.

Manage Backup Files

Click the Delete button to delete a created backup.

Click the Download button to download a created backup. The backup file can later be used to restore from file.

See the Cloud Service section for details.

The alarm light is authorized through the license management feature. This interface allows you to view the current license status and usage.

If you need to obtain more license authorizations, please contact our company.

This page displays device information and provides online upgrade and USB upgrade functions.

Check for Updates: Checks for the latest version. If the current version is the latest, clicking Install Latest Version will execute the current version reinstallation process.

Used to restart the device. Click the Execute button to perform the restart operation.

Scheduled Restart of Alarm Light: Click the Scheduled Restart button to open the settings dialog and set the restart time (only one rule is allowed).